12V DC
Items 1 - 20 of 88
Quick-filter
- All manufacturers
- operating temperatur (°C)
- RTC clock accuracy
- Analog inputs - measuring range
- Delay of operation
- Rated load DC
- Tightening torque
- Power consumption
- cycle time
- switching current (A)
- Number of channels
- Contact Form
- Dimensions
- phase number
- No of poles / contacts
-
time relay functions
1÷12 min.1÷15 min.A - Switch-off delay after power failureAUTO - ON for time interval by voltage/contactB - cyclical operation controlled by contactBi - pulse first, symmetrical cyclicalBp - pause first, symmetrical cyclicalE - ON delayE(R) - ON delay with the Reset functionE(S) - ON delay, with time measurement stopped with contact SER - ON delay and OFF delay with control contact SEs - ON delay with the control contact SEsa - ON and OFF delayEsp - ON delay - one cycle, with closing of the control contact SEst - ON delay with closing of the control contact SEWa - OFF delay and breaking time delay with opening of the control contact SEWf - ON delay and OFF delay with the control contact SEWs - ON delay and ON for the set time with closing of the control contact SEWu - ON delay for the set intervalIi + Ip - Cyclical operation in two independent intervals T1 and T2nWa - ON for a time, when voltage is off.nWs - latching ON delaynWu - ON for time, by ON supply voltagenWuWa - single shot leading + trailing edgeON / OFF - permanent switchingPi - Cyclical operation pulse firstPi(S) - Cyclical operation pulse firstPp - Cyclical operation pause firstPp(S) - Cyclical operation pause firstR - OFF delay through control contactR - OFF delay with the control contact SRa - OFF delay with the control contact S, without the interval T extensionT - generation of the 0,5 s pulseWa - ON for intervall by opening contactWi - Time interval controlled by voltageWs - single shot by closing contactWsWa - ON for the set intervals with the control contact SWt - Monitoring of the sequence of pulsesWu - ON for the set intervalWu(R) - ON for the set interval with the Reset functionWu(S) - ON for the set interval, with time measurement stopped with contact S closingWst - ON for the set interval by closing the control contact S, with extension of the interval TEsf - ON delay with the control contact S, without the interval T extensionSD - Star-Delta start-upBp(S) - Symmetrical cyclical operation pause first, with interval T measurement stopped for the time the S contact is switched onBi(S) - Symmetrical cyclical operation pulse first, with interval T measurement stopped for the time the S contact is switched onEsa(R) - ON and OFF delay controlled with on and off of the S contact with the Reset functionP (FiF) - Programmable
- Outputs - continuous current. resistive load
- Rated load AC
- Analog inputs - resolution
- lifetime of the program
- Processing time of a single application
- supply voltage
- Number of event counters
- Number of time counters (10 ms)
- Number of math blocks
- number of function blocks
- Outputs - electrical life. resistive load
- Outputs - mechanical life
- number Inputs
- Total number of entries
- Number of digital inputs
- Inrush current (max)
- high inrush
- switching voltage (max)
- Number of HMI screens
- Number of expansion modules
- number Outputs
- Outputs - number of outputs
- Outputs - continuous current. inductive load
- RTC clock support
- Insulation rated voltage
- Number of digital flags
- Number of analog registers
- switching time (adjustable)
- power consumption
- Number of PI controllers
- output voltage
- Number of free inputs (4Hz)
- Number of fast inputs (60 kHz)
- Number of analog inputs
- number program memory cells
- Resistance to sudden power failure
- Operating threshold
- Contact material
-
Manufacturer series
AS - F&FBIS Series - F&FEIR series - elovoltG2RL - OmronG5V-1 - OmronG6K - OmronG6RN - OmronHF41F - HongfaMT - RelpolNEED - RelpolPCZ Series - F&FR2N - RelpolR4N - RelpolRM12 - RelpolRM40 - RelpolRM51 - RelpolRM699 - RelpolRM85 - RelpolRM87N - RelpolRM96 - RelpolRPB - RelpolRPC - RelpolRPI-P Series - RelpolRPI-Z Series - RelpolShelly PRO-Seriesshelly - flush-mounted
- product type
- Smart Conect
- Assembly
- Functions
- suitable for (lamps)
- protection category
- Display
- Status memory after power failure
- Dedicated central control inputs
- Separation of the contact
- Cooperation with illuminated buttons
- Terminal
- Ausgänge – Ausgang Produkttyp
- Outputs - Output product type
- control panel
- Switching off indication
- RS232
- HMI-Panel
- Protection against data loss
- Accuracy
- Operating threshold
- Dielectric strength
- tripping delay
- Time of clock operation
- Wi-Fi protocol
- Control pulse current
- executive element
- Signal LED color