DIN-Rail
Pre-order possible
No
Yes
Installation relays
34
LED and lighting relays
8
Programmable timers
8
Roller blind and awning control
6
shelly
12
SPS Programmable relays
3
Staircase timers
10
twilight switches
9
Lighting timerelays
8
Time Relays
75
Power supply
32
Installation contactors
80
Impulse switch relay
44
phasecontrol
31
Fuse modules
6
smartmeters
24
1÷12 min.
A - Switch-off delay after power failure
AUTO - ON for time interval by voltage/contact
B - cyclical operation controlled by contact
Bi - pulse first, symmetrical cyclical
Bp - pause first, symmetrical cyclical
E - ON delay
E(R) - ON delay with the Reset function
E(S) - ON delay, with time measurement stopped with contact S
ER - ON delay and OFF delay with control contact S
Es - ON delay with the control contact S
Esa - ON and OFF delay
Esp - ON delay - one cycle, with closing of the control contact S
Est - ON delay with closing of the control contact S
EWa - OFF delay and breaking time delay with opening of the control contact S
EWf - ON delay and OFF delay with the control contact S
EWs - ON delay and ON for the set time with closing of the control contact S
EWu - ON delay for the set interval
Ii + Ip - Cyclical operation in two independent intervals T1 and T2
nWa - ON for a time, when voltage is off.
nWs - latching ON delay
nWu - ON for time, by ON supply voltage
nWuWa - single shot leading + trailing edge
ON / OFF - permanent switching
Pi - Cyclical operation pulse first
Pi(S) - Cyclical operation pulse first
Pp - Cyclical operation pause first
Pp(S) - Cyclical operation pause first
R - OFF delay through control contact
R - OFF delay with the control contact S
Ra - OFF delay with the control contact S, without the interval T extension
T - generation of the 0,5 s pulse
Wa - ON for intervall by opening contact
Wi - Time interval controlled by voltage
Ws - single shot by closing contact
WsWa - ON for the set intervals with the control contact S
Wt - Monitoring of the sequence of pulses
Wu - ON for the set interval
Wu(R) - ON for the set interval with the Reset function
Wu(S) - ON for the set interval, with time measurement stopped with contact S closing
Wst - ON for the set interval by closing the control contact S, with extension of the interval T
Esf - ON delay with the control contact S, without the interval T extension
SD - Star-Delta start-up
Bp(S) - Symmetrical cyclical operation pause first, with interval T measurement stopped for the time the S contact is switched on
Bi(S) - Symmetrical cyclical operation pulse first, with interval T measurement stopped for the time the S contact is switched on
Esa(R) - ON and OFF delay controlled with on and off of the S contact with the Reset function
EAnW (FiF) - Timerelay with delayed pulses
M (FiF) - Multifunction
P (FiF) - Programmable
B (FiF) - cyclical operation
L (FiF) - interruption after power failure
A (FiF) - Switch-Off delay
100V to 265V AC
100V to 265V AC/DC
100V to 277V AC
10V to 27V DC
10V to 30V AC/DC
115V AC
12V to 240V AC/DC
12V AC
12V DC
130V to 260V AC/DC
165V to 265V AC
18V DC
195V to 253V AC
230V AC
230V DC
24V AC
24V AC/DC
24V DC
24V to 260V AC/DC
24V to 264V AC/DC
2V DC
3×230 V+N
30V DC
30V to 130V AC/DC
48V DC
50V DC
5V to 10V AC/DC
60V DC
85V to 265V AC/DC
9V DC
9V to 30V AC/DC
9V to 30V DC
24V to 240V AC/DC
9V to 265V AC/DC
110V AC
12V AC/DC