Building and safety technology
Items 1 - 20 of 27
- SKU:
- 102758
Fuse module for DIN rail, 3 fuse sockets for fuse Ø5×20 mm, max 250 V AC/DC, max 6.3A ATTENTION! Fuse NOT included.
- SKU:
- 102805
Fuse module for DIN rail, 2 fuse sockets for fuse Ø5×20 mm, max 250 V AC/DC, max 6.3A ATTENTION! Fuse NOT included.
- SKU:
- 102917
Current 63 A. 24 V AC/DC voltage. Power AC1 24 kW. Power AC3 8.5 kW.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
- SKU:
- 102894
Current 25 A. Voltage 24 V AC. Power AC1 4 kW. Power AC3 1.3 kW.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
- SKU:
- 102910
Current 63 A. Voltage 230 V AC. Power AC1 24 kW. Power AC3 8.5 kW.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
- SKU:
- 102851
Electronic bi-stable pulse relays BIS-414 230 V enables the user to actuate lighting or other devices from various locations by means of control buttons in parallel connection.
Single function. Power supply 230 V AC. Maximum load 2 x16 A. On TH-35 mm rail. Can be used with backlit buttons.
Single function. Power supply 230 V AC. Maximum load 2 x16 A. On TH-35 mm rail. Can be used with backlit buttons.
- SKU:
- 102987
Output voltage 12 V. Power 60 W.
The switched-mode power supply is used to supply electric and electronic devices that require a stable, filtered supply voltage independent of changes in the mains voltage.
The switched-mode power supply is used to supply electric and electronic devices that require a stable, filtered supply voltage independent of changes in the mains voltage.
- SKU:
- 102940
MID compliant. Single-phase. Current 50A.
LE-01d is a static (electronic) calibrated electricity meter of single-phase alternating current in a direct system.
LE-01d is a static (electronic) calibrated electricity meter of single-phase alternating current in a direct system.
- SKU:
- 103016
Two states. Two LEDs: green, red. Voltage range 130-260 V AC/DC.
The signal light LK-714 is used for optical signaling circuits or states listed receivers, such as closed - open; work - break, etc.
The signal light LK-714 is used for optical signaling circuits or states listed receivers, such as closed - open; work - break, etc.
- SKU:
- 102849
Electronic bi-stable pulse relays enables the user to actuate lighting or other devices from various locations by means of control buttons in parallel connection.
Power supply 230 V AC. Maximum load 16 A. On TH-35 mm rail. With timing switch. Can be used with backlit buttons.
Power supply 230 V AC. Maximum load 16 A. On TH-35 mm rail. With timing switch. Can be used with backlit buttons.
- SKU:
- 103011
Three phases. Three LEDs. Color green.
The light signal LK-713 is used for optical signals the presence of voltage in the phases of three-phase network.
The light signal LK-713 is used for optical signals the presence of voltage in the phases of three-phase network.
- SKU:
- 102920
Modular contactor with manual control
Rated operating current 40 A.
Rated operating voltage 250 V AC.
Electromagnetic contactors in modular enclosures for direct mounting on TH-35 mm rail.
Rated operating current 40 A.
Rated operating voltage 250 V AC.
Electromagnetic contactors in modular enclosures for direct mounting on TH-35 mm rail.
- SKU:
- 102859
Electronic bistable impulse relay allows switching of lighting or other equipment from several different points of using the control buttons are connected in parallel.
Relay version "i" is to pin adapted to cooperate with the receivers with high starting current, such as LED fluorescent lamps, ESL fluorescent lamps, electronic transformers, discharge lamps, etc.
Power supply 230 V AC. Maximum load 16 A (160 A/20 ms). On TH-35 mm rail. Can be used with backlit buttons.
- SKU:
- 102884
The electronic bistable relay enables switching on the lighting or other device from several different points by means of parallel connected control buttons.
Sequential. Power supply 230 V AC . Maximum load 2 x 16 A (160 A / 20 ms). On the 35 mm rail. Can be used with backlit buttons.
Sequential. Power supply 230 V AC . Maximum load 2 x 16 A (160 A / 20 ms). On the 35 mm rail. Can be used with backlit buttons.
- SKU:
- 102941
Single-phase, two-way, four-quadrant electrical energy measurement and network parameters, compliant with the MID directive, M-Bus communication interface.
- SKU:
- 102915
Current 25 A. Voltage 24 V DC. Power AC1 4 kW. Power AC3 1.3 kW.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
- SKU:
- 102909
Current 63 A. 24 V AC voltage. Power AC1 24 kW. Power AC3 8.5 kW.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
Electromagnetic contactors in modular case for direct mounting on rail 35mm.
- SKU:
- 102856
The BIS-412P electronic bistable pulse relay is designed for group operation. A single relay allows the controlled receiver to be switched on and off after each current pulse caused by pressing the momentary (bell) button of the local control connected to this relay.
- SKU:
- 102881
Electronic bi-stable pulse relays BIS-414i 24 V enables the user to actuate lighting or other devices from various locations by means of control buttons in parallel connection.
Single function. Power supply 24 V AC. Maximum load 2 x 16 A (160 A/20 ms). On TH-35 mm rail.
Single function. Power supply 24 V AC. Maximum load 2 x 16 A (160 A/20 ms). On TH-35 mm rail.
- SKU:
- 102957
Single-phase. Maximum current 45A.
LE-01 is static (electronic) a calibrated indication of the electricity consumption of single-phase alternating current system directly.
LE-01 is static (electronic) a calibrated indication of the electricity consumption of single-phase alternating current system directly.
Items 1 - 20 of 27