Functioning
The clock at programmed hours in the following cycles: daily, weekly, working days (Mon-Fri) or weekend (Sa.-Su.) sets the brightness level of the output circuit at a given level (range 0-100%). Up to 500 independent program steps can be programmed. The controller is equipped with a local input enabling remote control of the controller by means of any monostable button.
Timer features
AUTOMATIC OPERATION - operation by ON-OFF COMMANDS programmed by the user in the timer memory [ icon on display is switched on]
MANUAL OPERATION - manual control (with the button connected to the controller) over the switching-on, switching-off and level of brightness
SEMI-AUTOMATIC OPERATION - operation in automatic mode can be inter-rupted to manually (with external button) set the brightness level. Semi-automatic operation continues until manual return to the automatic mode or until the next step of the program is started.
ON-OFF COMMAND - program entry according to which the receiver will be turned on or off.
OPERATION CYCLE - adjustable, weekly cycle of the receiver switching in accordance with the programmed commands:
* single day of the week: Mo. Tu. We. Th. Fr. Sa. or Su.
* business days: Mo. Tu. We. Th. Fr. (Monday to Friday).
* weekend: Sa. Su. (Saturday and Sunday)
* daily: Mo. Tu. We. Th. Fr. Sa. Su. (Monday to Sunday).
AUTOMATIC TIME CHANGE - Changing time from winter to summer is automatically done at night on the last Saturday/Sunday of March. Changing time from summer to winter is done on the last Saturday/Sunday of October. The controller has a time zone selection feature, so that the switching time is consistent with local time.
DATE PREVIEW - Pressing the OK button displays the set date in the format: dd-mm-yy.
CURRENT PROGRAM PREVIEW - If the timer operates in automatic mode, then the subsequent pressing of the Up/Down button in the date preview mode will display information about the number and details of the currently running program.
CLOCK FREQUENCY ADJUSTMENT - Ability to freely accelerate/decelerate the timer. For example, if the controller starts to run slow 5 seconds per month over time, you can programmatically correct the deviation.
REPLACEABLE BATTERY (type 2032) - The controller is provided with a battery status monitor in case of a main power failure. If the battery is low, you will be informed that you need to replace it.
LCD BRIGHTNESS ADJUSTMENT - Changing the display contrast allows you to obtain clear LCD reading for different viewing angles.
RELAY STATE MEMORY - The set state of the relay in manual mode is saved also after power failure.
GTIN: | 5902431670133 |
HAN: | PCZ-531LED |
Category: | Programmable timers |
supply voltage: | 9V DC, 12V DC, 24V DC, 9V to 30V DC |
switching current (A): | 8 A |
operating temperatur (°C): | -20 / +50 °C |
Manufacturer series: | PCZ Series - F&F |
protection category: | IP20 |
Assembly: | DIN-Rail |
product type: | programmable control timer |
Tightening torque: | 0.5 Nm |
Terminal: | pluggable terminal blocks 4.0 mm² |
number program memory cells: | 480 |
Time of clock operation: | 6 years |
Accuracy: | 1s |
executive element: | transistor |
Item weight: | 0,4000 kg |
Manufacturer according to GPSR
F&F Filipowski Sp.k., Sikorskiego 15, 95-200 Pabianice, Polen, biuro@fif.com.pl, https://www.fif.com.pl
Responsible person according to GPSR
F&F, Sikorskiego 15, 95-200 Pabianice, Polen, biuro@fif.com.pl, https://www.fif.com.pl